ESR Analyzer (Micro SED-10)
Features & Benefits
Smart Technology
- Modern IR microtrchnology
- Robust performance & greater efficiency
- Real time detection of specimens
- Real time measurement and reporting of results temperature compensation
- Automatic compensation referred to 18 c ( manley)
- Result: in westergren mm/hr (by interpolation)
Ease of use
- Easy start up
- Simply plug into an on-line UPS and start testing no training required : no special expertise required fully automated
- Auto start of measurement
- Quick turn- around time: easy set up of tests
- Add specimen to tube
- Place tube in analyzer
- Results within 30 minutes
Complete flexibility
- Random access
- Use any open chamber to automatically measure, time and report result
- Provides convenience and flexibility to run tests at any time and in any order
- No batching of samples
- Each reading chamber individually timed for results
Quality and reliability of results
- Reliability of results
- Good correlation to 1 hour westergren method excellent reproducibility (cv of 5%)
- Accuracy & consistency of results
Productivity Advantage
- Measuring time: 30 minutes
- 20 tests per hour
- Optimization of lab work flow network capability
- Printer helps automatic prints patient results
- Eliminating transcription errors
- Date management software (dms) for easy management
- Compact size desktop analyzer thus minimal space required
Advanced FeaturesGraphical printout of results, if it is connected to a printer (which is optional) Safety Of Handling
- Reduced contact with potentially infectious hazardous blood specimen
- Completely " closed analysis system" (while using vacuum ESR tube for testing) prevents the user from potentially hazardous blood specimen
Technical Specifications
|
Application
|
blood sedimenatation rate analysis
|
|
Loading capacity
|
maximum 10 samples
|
|
Loading pattern
|
random access
|
|
Reading chambers
|
10(ten)
|
|
Analytical capacity
|
maximum 20 tests/ hour
|
|
Loading capacity
|
maximum 10 samples at a time
|
|
Analysis time
|
30 minutes
|
|
Throughput
|
20 specimens per hour
|
|
Results
|
in westergren mm/hour(by interpolation
|
|
Test tube
|
1.1 ml -1.28 ml blood
|
|
Temperature correction
|
results auto corrected to 18 c ( manley method)
|
|
Measurement principle
|
infrared (ir) detection
|
|
Reading resolution
|
+/-.02. mm (mechanical/ optical precision - detection by software controlled by encoder resolution)
|
|
Result resolution
|
+/-1 mm
|
|
Blood draw level
|
+4 mm/-10mm from acceptable range
|
|
Measurement range
|
1-140 mm/hr
|
|
Reproducibility
|
c.v <5% (sample dependent)
|
|
Display
|
lcd 40x2 with back-light
|
|
Interface
|
lpt for printer # &rs 232 for computer
|
|
Dimensions (w x h x d )
|
22 cm x 21.6 cm x 17.5 cm
|
|
Operating conditions
|
temperature 15 c ~ 31c humidity 45% ~ 85%
|
|
Weight
|
~ 2.5 kg
|
|
Power adaptor
|
input 110-220v ac 50/60 hz output 5v 3a
|
|
Power for analyzer
|
input 5v 3a
|
|
Software
|
integrated according to software version
|
|
Esr tubes
|
8/120 mm, 1.6 ml vacuum / non- vacuum ESR
|
|
Conformity
|
ISO 13485 & ce
|